Table of Contents
ToggleAS/NZS 61347.1:2016 Amendment 3:2026 – Updated Lamp Controlgear Safety Requirements
AS/NZS 61347.1:2016 has been reissued to incorporate Amendment 3:2026, published on 24 July 2026. The update concerns general safety requirements for lamp controlgear used in lighting equipment across Australia and New Zealand.
The amendment is relevant to lighting equipment manufacturers, electrical contractors, product certification professionals, lighting designers and businesses responsible for specifying electrical equipment.
It may also be relevant to professionals working with emergency lighting systems, where applicable controlgear standards form part of the product safety framework.
For the fire safety and building services industries, the important question is not simply whether a standard has changed, but whether the amendment affects equipment specifications, testing documentation, product certification or future purchasing decisions.
What Changed in AS/NZS 61347.1:2016?
The standard was reissued on 24 July 2026, incorporating Amendment No. 3.
The updated publication retains the designation AS/NZS 61347.1:2016 and includes the latest amendment within the consolidated standard.
| Item | Details |
|---|---|
| Standard | AS/NZS 61347.1:2016 |
| Title | Lamp controlgear – General and safety requirements |
| Latest amendment | Amendment 3:2026 |
| Reissue date | 24 July 2026 |
| Previous incorporated amendment | Amendment 2:2025 |
| Main subject | Electrical and mechanical safety of lamp controlgear |
| Primary audience | Manufacturers, electrical contractors, testing laboratories and certification professionals |
The standard adopts IEC 61347-1:2015 with Australian and New Zealand modifications.
Its scope includes general requirements for controlgear intended for use with luminaires operating on DC supplies up to 250 V or AC supplies up to 1,000 V at 50 Hz or 60 Hz.
The requirements address classification, marking, mechanical construction and electrical construction.
Important: Publication of an amendment does not automatically mean that every installed lighting system must be replaced or upgraded. Applicable regulatory requirements, certification arrangements and project specifications must be assessed separately.
Key Technical Areas Associated With Amendment 3:2026
The 2026 amendment has been associated with updates to several technical safety areas, including electrical insulation, protection and testing.
The following topics are relevant when reviewing the amended requirements.
1. Surge Protective Device Requirements
Surge protective devices (SPDs) help protect electrical equipment against transient overvoltages.
Changes involving surge protection can affect how controlgear is assessed and how protection components are considered during product design and testing.
Manufacturers and certification professionals should confirm the applicable SPD requirements in the amended standard before making design or compliance decisions.
2. SELV Marking and Electrical Safety
Safety Extra-Low Voltage (SELV) arrangements are used to reduce electrical shock risks through appropriate voltage limits and protective separation.
Marking requirements help identify relevant electrical characteristics and safety classifications.
Where SELV marking is applicable, manufacturers should verify that product labels, technical documentation and test reports reflect the amended requirements.
3. Creepage Distances and Electrical Clearances
Electrical insulation design is an important part of lamp controlgear safety.
Two key concepts are:
- Creepage distance: The shortest distance along the surface of insulating material between conductive parts.
- Clearance: The shortest distance through air between conductive parts.
These distances help reduce the risk of electrical breakdown and insulation failure.
Any applicable changes to these requirements should be assessed against the product’s operating voltage, insulation design and intended environment.
4. Terminal and Connection Requirements
Electrical terminals and connections must be suitable for the equipment’s intended operating conditions.
Relevant considerations include secure conductor connections, electrical continuity, mechanical integrity and safe installation.
Manufacturers should review the amended clauses when confirming terminal designs and product testing requirements.
5. Insulation Classification and Thermal Testing
Lamp controlgear can generate heat during normal operation.
Appropriate insulation and temperature management are important for electrical safety and reducing overheating risks.
The amendment has also been associated with insulation classification for metal-core printed circuit boards (MCPCBs) and heating or temperature-rise test conditions.
These subjects may be relevant to electronic lighting equipment and LED controlgear.
Verification note: The technical topics above identify areas reported in connection with Amendment 3:2026. They are not a complete clause-by-clause summary. The exact amended wording, test conditions and compliance implications must be confirmed against the published amendment.
Why Does This Amendment Matter for Electrical Contractors?
Electrical contractors may encounter lamp controlgear when installing, replacing or maintaining lighting systems in commercial, industrial and residential buildings.
The updated standard provides a reason to review the technical documentation used for new equipment.
Contractors should consider:
- Whether the specified controlgear references the appropriate standard.
- Whether supplier documentation identifies the applicable amendment.
- Whether the equipment is suitable for the installation conditions.
- Whether replacement products meet the project specification.
- Whether any new certification or test documentation is required.
The amendment should not be interpreted as a blanket requirement to replace existing equipment.
For installed systems, decisions should be based on the applicable regulatory framework, equipment condition, manufacturer instructions and any relevant safety findings.
Does AS/NZS 61347.1 Amendment 3:2026 Affect Emergency Lighting?
Potentially, but its application must be assessed carefully.
Emergency lighting equipment may contain electronic controlgear, battery charging components, control circuits and other electrical components.
The AS/NZS 61347 family includes general lamp controlgear safety requirements and particular requirements for certain equipment types.
For example, AS 61347.2.7:2019 addresses battery-supplied electronic controlgear for self-contained emergency lighting.
This creates a technical connection between the general lamp controlgear standard and some emergency lighting products.
However, Amendment 3:2026 to AS/NZS 61347.1 does not automatically amend every emergency lighting standard.
Important Standards to Distinguish
| Standard | Main purpose |
|---|---|
| AS/NZS 61347.1 | General safety requirements for lamp controlgear |
| AS 61347.2.7 | Particular requirements for battery-supplied electronic controlgear for self-contained emergency lighting |
| AS/NZS 2293.1 | Emergency lighting and exit signs – System design, installation and operation |
| AS/NZS 2293.2 | Emergency lighting and exit signs – Routine service and maintenance |
| AS/NZS 2293.3 | Emergency lighting and exit signs – Emergency luminaires and exit signs |
The distinction matters for fire protection and building services professionals.
A change to a component safety standard should not be confused with a change to routine emergency lighting inspection intervals or maintenance procedures.
Before updating emergency lighting specifications or service documentation, the responsible professional should confirm which standards apply to the particular equipment and installation.
What About Fire Detection and Fire Protection Systems?
AS/NZS 61347.1 is primarily a lamp controlgear safety standard.
It is not a direct amendment to AS 1851, and it does not establish new routine servicing requirements for fire hydrants, sprinklers, fire pumps or fire detection systems.
Its relevance to the broader fire safety industry is mainly through electrical equipment safety, lighting infrastructure and potentially emergency lighting components.
Fire protection contractors working alongside electrical and building services teams should understand this distinction when reviewing new standards or advising customers.
What Should Manufacturers and Suppliers Review?
Businesses manufacturing, importing or supplying applicable lamp controlgear should consider whether Amendment 3:2026 affects their product documentation or conformity assessment.
A practical review may include:
- Product identification: Identify models assessed against AS/NZS 61347.1:2016.
- Standards review: Obtain the amended publication and identify relevant technical changes.
- Testing documentation: Check whether existing reports cover the amended requirements.
- Certification: Confirm with the responsible certification body whether further assessment is required.
- Product information: Review technical specifications, markings and installation instructions.
- Regulatory requirements: Check which edition and amendment are applicable in the relevant jurisdiction.
This process helps businesses avoid assuming that a newly published amendment automatically changes every existing product approval.
Is Amendment 3:2026 Mandatory in Australia?
Publication of an Australian/New Zealand Standard and legal adoption of that standard are separate matters.
A standard may become relevant through legislation, regulatory instruments, certification schemes, contractual requirements or project specifications.
The publication of Amendment 3:2026 alone does not establish that every Australian business must immediately upgrade or replace existing lamp controlgear.
Businesses should confirm the requirements applicable to their products, installation activities and jurisdiction.
For regulatory context, refer to:
- Australian Building Codes Board – National Construction Code
- Australian Government – Electrical Equipment Safety System
- Standards Australia – Standards and Amendments Information
For cross-jurisdictional context, New Zealand’s official Electricity (Safety) Regulations also identify the AS/NZS 61347 family within requirements for certain lamp controlgear products. The specific amendment edition referenced in legislation must be checked separately.
What Should Facility Managers Do?
Facility managers do not necessarily need to take immediate action simply because the standard has been amended.
However, the update provides an opportunity to improve purchasing and maintenance documentation.
For new lighting projects or replacement work, consider:
- Checking the applicable product standard.
- Requesting current technical documentation.
- Confirming equipment compatibility.
- Recording model numbers and replacement details.
- Reviewing installation instructions.
- Keeping relevant certification information available.
Where equipment forms part of an emergency lighting installation, its maintenance should continue in accordance with the applicable emergency lighting requirements.
Frequently Asked Questions
What is AS/NZS 61347.1:2016 Amendment 3:2026?
It is the third amendment to AS/NZS 61347.1:2016, the Australian/New Zealand standard covering general safety requirements for lamp controlgear. The standard was reissued incorporating Amendment 3 on 24 July 2026.
What equipment does AS/NZS 61347.1 cover?
It covers general safety requirements for lamp controlgear intended for use with luminaires, within the electrical supply limits specified by the standard.
What are the main technical areas associated with the 2026 amendment?
Reported areas include surge protection, SELV marking, electrical clearances, creepage distances, terminals, insulation classification and thermal testing. The exact changes should be verified against the amendment text.
Does the amendment affect emergency lighting?
It may be relevant to applicable controlgear used in emergency lighting equipment. However, it does not automatically change the design or maintenance requirements of the AS/NZS 2293 series.
Do existing lighting systems need to be replaced?
Not automatically. The amendment’s publication alone does not establish a universal replacement requirement. Any necessary action depends on applicable regulations, equipment certification, project requirements and identified safety issues.
Does Amendment 3 change AS 1851 requirements?
No direct amendment to AS 1851 is established by this publication. AS 1851 addresses routine servicing of applicable fire protection systems and equipment, while AS/NZS 61347.1 addresses lamp controlgear safety.
Where can businesses confirm the updated requirements?
Businesses should consult the published AS/NZS 61347.1:2016 standard incorporating Amendment 3:2026, together with relevant regulator guidance and certification requirements.
Conclusion
The July 2026 reissue of AS/NZS 61347.1:2016 incorporating Amendment 3 is an important technical update for businesses involved in lighting equipment design, manufacturing, certification and electrical installation.
The amendment highlights the need to keep product safety documentation and testing requirements aligned with the applicable standards.
For electrical contractors and fire protection professionals, the most important step is to understand the amendment’s scope and avoid confusing lamp controlgear safety requirements with emergency lighting maintenance or AS 1851 fire protection servicing obligations.
Fire Factory Australia continues to share relevant Australian fire safety, electrical and building services standards updates to help industry professionals stay informed.
Visit Fire Factory Australia for fire protection products, fire-rated cables, service logbooks and industry information.
Official Sources and Further Reading
- Standards Australia – Understanding Standards and Amendments
- Australian Government – Electrical Equipment Safety System
- Australian Building Codes Board – National Construction Code
- New Zealand Government – Electricity (Safety) Regulations 2010
Source note: The amendment’s publication date and consolidated standard history are confirmed by the published standards catalogue. The government resources above provide regulatory context; they are not a substitute for the full text of Amendment 3:2026.