With silicon gaskets for smoke and fire door applications
Min/Max Gap: 3mm to 13mm
Feature: Intumescent Fire Protection
Finish: Satin clear (silver)
Seal: Grey silicon rubber
Length: 820mm and 920mm.
Min/Max Gap: 3mm to 15mm
Finish: Satin clear (silver)
Seal: Grey silicon rubber
Length: 820mm and 920mm.
Min/Max Gap: 3mm to 13mm
Finish: Satin clear (silver)
Seal: Grey silicon rubber
Length: 920mm.
Min/Max Gap: 3mm to 14mm.
Finish: Satin clear (silver),
Seal: Grey silicon rubber
Length: 920mm.
Flex seal has the flexible nature which allows it to be used for many applications where a rigid strip would be impractical.
Self adhesive fixing
Coils packing and minimize wastage
Dimensions: 20mm x 2 mm x 25m Roll
Gap Size: Intumescent seal fills gaps up to 6 mm
Materials: Consists of a flame retardant PVC top hat section, encapsulating a high performance intumescent material and two rows of aggressive self-adhesive tape
Dimensions: 38mm x 2mm x 2100mm
A non-combustible silicate sheet that expands under fire to form a hard, pressure-resistant, heat-insulating barrier. It blocks fire and smoke and protects underlying surfaces.
Density: Approx. 1.25 g/cm³ to 1.35 g/cm³
Expansiontemperature: Starting from100℃-120℃
Expansionfactor: up to 10-fold its original thickness
Dimensions: 15 x 4 x 2100 mm
Fire & smoke seal for fire-rated doors, designed to slow the spread of smoke in fire conditions. It features an exfoliated graphite core that expands up to 10× when exposed to heat.
Density: Approx. 1.25 g/cm³ to 1.35 g/cm³
Expansiontemperature: Starting from100℃-120℃
Expansionfactor: up to 10-fold its original thickness
Dimensions: 15 x 4 x 2100 mm
Fire door seals help slow fire spread by sealing door gaps. When exposed to heat, they expand to help block flames and heat transfer. This improves fire containment and helps protect people and property.
Smoke seals help reduce smoke spread by sealing gaps around the door. They help limit smoke movement between rooms and escape paths, improving safety during an emergency. This helps create safer evacuation routes and reduces smoke transfer.
Door seals help minimise unwanted noise by closing gaps around the door. They reduce sound transmission between rooms and from outside areas. This creates a quieter, more comfortable environment and improves privacy.
Door seals help reduce energy loss by sealing gaps around the door. They prevent hot or cold air from escaping and block drafts from entering. This improves insulation, keeps indoor temperature stable, and lowers heating and cooling costs.
Door seals help prevent insects from entering by closing gaps around the door. They block small openings that bugs use to get inside. This keeps your space cleaner, more hygienic, and more comfortable.
Unit 2, 2 Parramatta Road, Granville, NSW, 2142
(02)7209 5582
10 Victoria Street, SMITHFIELD, NSW, 2164
(02)9756 0087
A concealed, medium-duty automatic door drop seal, spring-loaded to lift clear of the floor when the door opens. Designed for acoustic performance, it features silicon gaskets suitable for smoke and fire door applications. The seal is activated by pressure against the door jamb using an adjustable strike, ensuring consistent operation and a tight seal. It effectively blocks fire, smoke, noise and insects, and can be installed on both internal and external doors.
Fully morticed into a 15mm × 34mm groove at the bottom of single and double hinged timber or metal doors. Includes level adjustment for optimal sealing performance.
Available Sizes: 820mm and 920mm
Min/Max Gap: 3mm to 13mm
Finish: Satin clear (silver)
Seal: Grey silicon rubber
Built with high-quality materials for reliable performance, durability, and long service life in demanding applications.
A surface-mounted automatic door drop seal designed for acoustic performance, featuring a durable aluminium alloy body with a high-quality silicon rubber seal. It automatically drops when the door closes, creating an effective barrier against noise, insects and drafts, and lifts clear when the door opens for smooth operation.
Suitable for single and double leaf doors, this seal is screw-fixed to either side of the door face, allowing quick and easy installation without the need for morticing.
Application: Single and double leaf doors
Material: Aluminium Alloy + Silicon Rubber
Color: Satin Anodised Aluminium (SAA) cover plate, light grey
Gap (mm): Min. 3mm / Max. 13mm
Dimension (mm): 14 × 47
Standard Length (mm):820mm, 920mm,
Fixing: Screw fix to either side of door face
Manufactured with high-quality materials for consistent performance, durability, and long service life in demanding applications.
A concealed, medium-duty automatic door bottom seal, spring-loaded to lift clear of the floor when the door opens. Designed for acoustic performance, it features silicon gaskets suitable for smoke and fire door applications. The seal is automatically activated by pressure against the door jamb using an adjustable strike, ensuring consistent operation and a tight seal.
Fully morticed into a 15mm × 34mm groove at the bottom of single and double butt hinged timber and metal doors. Includes level adjustment for optimal sealing performance.
Available Sizes: 920mm (allow 150mm for cutting)
Min/Max Gap: 3mm to 13mm
Finish: Satin clear (silver)
Seal: Grey silicon rubber
Built with high-quality materials for reliable performance, durability, and long service life in demanding applications.
A concealed, heavy-duty automatic door bottom seal, spring-loaded to lift clear of the floor when the door opens. Designed for acoustic performance, it features silicon gaskets suitable for smoke and fire door applications. The seal is automatically activated by pressure against the door jamb using an adjustable strike, ensuring consistent operation and a tight seal. It can also be fitted into the bottom rail of metal doors by the fabricator.
Fully morticed into a 21mm × 38mm groove at the bottom of single and double butt hinged timber and metal doors. Includes level adjustment for optimal sealing performance.
Available Sizes: 920mm
Min/Max Gap: 3mm to 14mm
Finish: Satin clear (silver)
Seal: Black silicon rubber
Heavy-duty construction ensures superior performance, durability, and long service life in demanding applications.
An intumescent retro-fit fire seal designed to upgrade door perimeter gaps where the clearance exceeds standard limits.
Suitable for perimeter gaps up to 6mm, this seal is easily applied to the top and sides of the door frame using two rows of aggressive self-adhesive tape. No screw fixing is required, making installation fast and efficient.
Dimensions: 38 × 2 × 2100mm
Color: White - Can be painted on-site to match door finishes.
Gap Range: Up to 6mm gaps
Key Features:
Provides up to 2 hours fire resistance on proprietary fire doors, Ideal for upgrading non-compliant fire doors, Allows use of standard steel frames instead of 25mm fire door stops, Suitable for fire-engineered safety solutions
Materials:
Flame-retardant PVC top hat section encapsulating a high-performance intumescent core, with two rows of aggressive self-adhesive tape.
A hard casing intumescent fire seal designed to expand rapidly when exposed to high temperatures, forming a voluminous foam that helps seal gaps against fire and hot gases. Ideal for sealing the air gap between door leaves and frames, as well as between double door leaves in fire-resistant door applications.
Supplied in a durable PVC casing with a clean finish. Wood grain patterns are available upon request. The product features a self-adhesive backing for easy and quick installation and is not affected by water, ensuring long-lasting performance in various environments.
Dimensions: 15 × 4 × 2100mm
Color: Brown
Expansion Ratio: up to 10-fold its original thickness
Features:
Hard PVC casing, Self-adhesive fixing, Water-resistant, Suitable for fire-rated doors
Designed for reliable fire protection, this seal enhances door integrity and helps prevent the spread of fire and smoke.
A combined fire and smoke seal featuring an exfoliated graphite core that expands up to 10 times its original volume when exposed to heat. Designed for use in fire-resistant doors, it helps seal gaps and retard the passage of fire and smoke in emergency situations.
The seal includes a 6mm pile (brush) mounted in a durable PVC holder, ideal for sealing typical gaps of 3mm to 4mm between the door and frame. Supplied in a high-quality PVC casing with various color options, including wood grain finishes upon request. Self-adhesive backing allows for quick and easy installation.
Dimensions: 15 × 4mm
Pile Height: 6mm
Gap Range: 3mm to 4mm
Expansion Ratio: up to 10-fold its original thickness
Color: brown
Features:
Exfoliated graphite intumescent core, Integrated smoke seal (pile brush), PVC casing with optional wood grain finish, Self-adhesive fixing
Engineered for reliable fire and smoke protection, this seal enhances door performance and helps maintain safe escape routes.

A comprehensive Fire And Smoke Control Features Of Mechanical Services logbook designed for recording routine service activities in accordance with AS 1851—2012 (Incorporating Amendment 1), Section 13.
It provides structured inspection, testing and survey schedules with dedicated areas for recording results, defects, comments and corrective actions. The logbook covers key fire and smoke control features of mechanical services, making routine servicing easier to document clearly and consistently.
| Size | 305 × 210 mm |
| Service Intervals | Monthly . Three-Monthly · Six-Monthly · Yearly |
Applications:
Fans & Motors, Fire & Smoke Dampers, Air Control Dampers, Automatic Smoke & Heat Vents, Fire & Smoke Curtains, Motorised Relief Openings, Windows & Shutters, Electric Heaters, Kitchen Exhaust Systems, Outdoor Intakes, Variable Frequency Inverters (Vfis), Pneumatic Compressor/Receiver Station, Motor Control, Centres Power Supplies, Fire Isolated Exit Pressurization Systems, Smoke Exhaust Systems, Smoke Control Systems, Smoke Reservoirs











A comprehensive passive fire logbook designed for recording routine service activities in accordance with AS 1851—2012 (Incorporating Amendment 1).
It provides structured inspection schedules and dedicated areas for recording asset numbers, Pass/Fail/N/A results, defects, comments, corrective actions and completed repairs. The logbook covers a wide range of passive fire systems, making routine inspections easier to document clearly and consistently.
| Size | 305 × 210 mm |
| Service Intervals | Three-Monthly · Six-Monthly · Yearly |
Applications:
Fire & Smoke Barriers · Walls, Floors & Ceilings · Service Penetrations & Control Joints · Access Panels & Hatches · Fire-Protected Structural Members · Fire-Resistant Doorsets · Horizontal Sliding Doors · Smoke Doors · Fire Shutters · Fire-Rated Glazing · Fire-Protected Air Ducts





A comprehensive one-year logbook designed for recording routine service activities for diesel and electric fire pumpsets and jacking pumps serving sprinkler and hydrant systems, in accordance with AS 1851—2012 (Incorporating Amendment 1).
It provides dedicated fields for pump operation, pressure and flow testing, starting pressures, batteries, engine and motor readings, jacking pump cut-in/cut-out pressures, defects and corrective actions, making routine service records clear and consistent.
| Size | 305 × 210 mm |
| Service Intervals | Monthly · Six-Monthly · Yearly · Five-Yearly |
Applications:
Sprinkler Fire Pumps · Hydrant Fire Pumps · Combined Sprinkler & Hydrant Pumps · Diesel Pumpsets · Electric Pumpsets · Jacking Pumps





A practical two-year logbook designed for recording routine service activities for Special Hazard Fire Suppression Systems in accordance with AS 1851—2012 (Incorporating Amendment 1).
It provides dedicated fields for system inspections, container condition and charge, detection and release systems, pressure tests, enclosure integrity, interfaces, water mist and aerosol systems, defects and corrective actions, helping technicians maintain clear and consistent service records.
| Size | 238 × 148 mm |
| Service Intervals | Monthly · Six-Monthly · Yearly · Five-Yearly |
Applications:
Gaseous Fire Suppression Systems · Aerosol Systems · Water Mist Systems · Other Special Hazard Fire Suppression Systems






A practical service logbook designed for recording routine inspection, testing and maintenance of Wet Pipe Sprinkler and Jacking Pump Systems in accordance with AS 1851—2012 (Incorporating Amendment 1).
It provides dedicated fields for pressure readings, alarm gong tests, pump cut-in and cut-out pressures, main drain tests, water supply proving tests, valve testing, defects and corrective actions, helping technicians keep service records clear, consistent and easy to complete.
| Size | 305 × 210 mm |
| Service Intervals | Monthly · Six-Monthly · Yearly · Five-Yearly |
Applications:
Wet Pipe Sprinkler Systems · Jacking Pumps






A comprehensive two-year logbook designed for recording routine service activities across fire detection, alarm, special hazard, smoke and heat alarm, emergency warning and intercom systems in accordance with AS 1851—2012 (Incorporating Amendment 1).
It combines key service schedules in one logbook, with dedicated fields for inspections, functional tests, system interfaces, battery readings, detector testing, sound pressure levels, speaker circuits, defects and corrective actions.
| Size | 305 × 210 mm |
| Service Intervals | Monthly · Six-Monthly · Yearly · Five-Yearly |
Applications:
Fire Detection & Alarm Systems · Smoke & Heat Alarms · Smoke Hazard Management Systems · Emergency Warning Systems (EWS) · Emergency Intercom Systems (EIS)

The BEEL – Exit & Emergency Lighting Inspection Report Book is an essential tool for maintaining fire safety and emergency lighting compliance. Designed for building managers, facility staff, and safety officers, this book provides a structured format to log inspections, test results, and maintenance actions for all exit and emergency lighting systems.
Size: A4










A comprehensive two-year logbook designed for recording routine service activities for delivery lay flat hoses, fire hose reels, fire extinguishers and fire blankets in accordance with AS 1851—2012 (Incorporating Amendment 1).
It includes routine service schedules, a dedicated equipment register for up to 100 items, and structured service records for inspections, testing, pressure tests, service tags, defects and corrective actions, helping technicians keep service records clear and consistent.
| Size | 305 × 210 mm |
| Service Intervals | Six-Monthly · Yearly · Five-Yearly |
Applications:
Delivery Lay Flat Hoses · Fire Hose Reels · Portable & Wheeled Fire Extinguishers · Fire Blankets





A practical two-year logbook designed for recording routine service activities for fire hydrant systems and associated jacking pumps, in accordance with AS 1851—2012 (Incorporating Amendment 1).
It provides dedicated fields for hydrant and booster inspections, pump starting pressures, pressure-reducing valves, water supply proving tests, hydrostatic and flow tests, jacking pump operation, defects and corrective actions, helping technicians maintain clear and consistent service records.
| Size | 238 × 148 mm |
| Service Intervals | Monthly · Six-Monthly · Yearly · Five-Yearly |
Applications:
Fire Hydrant Systems · Above-Ground & Below-Ground Hydrants · Booster Assemblies · Pressure-Reducing / Pressure-Relief Valves · Jacking Pumps





A practical two-year logbook designed for recording routine service activities for fire protection water storage tanks in accordance with AS 1851—2012 (Incorporating Amendment 1).
It provides dedicated fields for water levels, pressure tank readings, tank condition, liners, valves, alarms, cleaning and inspection activities, defects and corrective actions, helping technicians maintain clear and consistent service records.
| Size | 238 × 148 mm |
| Service Intervals | Monthly · Six-Monthly · Yearly · Five-Yearly · Ten-Yearly |
Applications:
Fire Protection Water Storage Tanks · Atmospheric Tanks · Pressure Tanks · Tanks with Liners · Rectangular Panel Tanks

A practical 4-year logbook designed for recording routine service activities for jacking pumps associated with fire hose reel systems, in accordance with AS 1851—2012 (Incorporating Amendment 1).
It provides dedicated fields for pump condition and operation, water supply, controller checks, cut-in and cut-out pressures, hydro-pneumatic accumulator pressure, defects and corrective actions, helping technicians maintain clear and consistent service records.
| Size | 227 × 148 mm |
| Service Intervals | Monthly · Six-Monthly |
Applications:
Fire Hose Reel Systems · Jacking Pumps



A practical two-year logbook designed for recording routine service activities for electric fire pumpsets and jacking pumps serving sprinkler and hydrant systems, in accordance with AS 1851—2012 (Incorporating Amendment 1).
It provides dedicated fields for pressure and flow testing, pump starting and run records, controller battery readings, motor performance, jacking pump cut-in/cut-out pressures, defects and corrective actions, helping technicians maintain clear and consistent service records.
| Size | 305 × 210 mm |
| Service Intervals | Monthly · Six-Monthly · Yearly · Five-Yearly |
Applications:
Electric Fire Pumpsets · Sprinkler Fire Pumps · Hydrant Fire Pumps · Combined Sprinkler & Hydrant Pumps · Jacking Pumps



A practical two-year logbook designed for recording routine service activities for diesel fire pumpsets and jacking pumps serving sprinkler and hydrant systems, in accordance with AS 1851—2012 (Incorporating Amendment 1).
It provides dedicated fields for pressure and flow testing, pump starting and run records, battery and engine readings, jacking pump cut-in/cut-out pressures, defects and corrective actions, helping technicians maintain clear and consistent service records.
| Size | 305 × 210 mm |
| Service Intervals | Monthly · Six-Monthly · Yearly · Five-Yearly |
Applications:
Diesel Fire Pumpsets · Sprinkler Fire Pumps · Hydrant Fire Pumps · Combined Sprinkler & Hydrant Pumps · Jacking Pumps




A practical two-year logbook designed for recording routine service activities for Dry-Pipe, Pre-Action, Deluge and Water Spray sprinkler systems in accordance with AS 1851—2012 (Incorporating Amendment 1).
It provides dedicated fields for pressure readings, air compressor tests, alarm operation times, nitrogen pressure, valves, foam testing, defects and corrective actions, helping technicians maintain clear and consistent service records. Where applicable, relevant Wet Pipe Sprinkler service activities are recorded separately in the associated logbook.
| Size | 305 × 210 mm |
| Service Intervals | Monthly · Six-Monthly · Yearly · Five-Yearly |
Applications:
Dry-Pipe Sprinkler Systems · Pre-Action Sprinkler Systems · Deluge Systems · Water Spray Systems





A practical two-year logbook designed for recording routine service activities for Emergency Warning Systems (EWS)and Emergency Intercom Systems (EIS) in accordance with AS 1851—2012 (Incorporating Amendment 1).
It provides dedicated records for system inspections, functional tests, battery measurements, system interfaces, warning signals, Warden Intercom Points (WIPs), defects and corrective actions.
| Size | 238 × 148 mm |
| Service Intervals | Monthly · Yearly · Five-Yearly |
Applications:
Emergency Warning Systems (EWS) · Emergency Intercom Systems (EIS) · Warden Intercom Points (WIP) · Visual Warning Devices (VWD)






A practical two-year logbook designed for recording routine service activities for fire detection and alarm systems in accordance with AS 1851—2012 (Incorporating Amendment 1).
It provides dedicated service records for monthly, six-monthly, yearly and five-yearly activities, with sections for test results, defects, corrective actions, battery readings, sound pressure levels, system interfaces and detector testing.
| Size | 238 × 148 mm |
| Service Intervals | Monthly · Six-Monthly · Yearly · Five-Yearly |
Applications:
Fire Detection & Alarm Systems · Smoke & Heat Alarms · Smoke Hazard Management Systems · Fire Detection & Control Equipment