FSP-951AUS-IV – Photo-optical sensor, – FlashScan (Notifier)

FSP-951AUS-IV – Photo-optical sensor, – FlashScan (Notifier)

Description

PDF Data Sheet

FSP-951AUS Addressable Photoelectric Smoke Detector – FlashScan® Intelligent Smoke Detector

The FSP-951AUS is an intelligent addressable photoelectric smoke detector designed to provide reliable early warning smoke detection for FlashScan® fire alarm systems. Using advanced optical sensing technology, the detector provides accurate smoke detection while helping minimise false alarms through intelligent system communication.

The FSP-951AUS communicates directly with the fire alarm control panel via the FlashScan® SLC loop and uses rotary decimal switches for simple device addressing. Designed for Australian fire alarm installations, the detector provides dependable performance across a wide range of commercial, industrial, and institutional applications.

Compatible with approved detector bases including the B501AUS series, the FSP-951AUS offers straightforward installation, reliable monitoring, and simplified maintenance for modern addressable fire detection systems.

Key Features:

  • Intelligent addressable photoelectric smoke detector
  • FlashScan® SLC communication protocol
  • Rotary decimal switch addressing (1–159)
  • 15–32 VDC operating range
  • Low standby current for efficient system operation
  • High-intensity LED status indicator
  • Compatible with B501AUS series and approved detector bases
  • Ivory finish for standard fire alarm installations
  • AS 7240.7 compliant for smoke detector applications

Typical Applications:

  • Commercial buildings
  • Offices and retail facilities
  • Schools and educational sites
  • Healthcare facilities
  • Industrial premises
  • Public buildings and accommodation facilities

The FSP-951AUS Addressable Photoelectric Smoke Detector provides dependable smoke detection, intelligent communication, and seamless integration with Notifier fire alarm systems, helping deliver effective fire safety protection for modern buildings.

Specifications

 

Parameter Description
Product Code FSP‑951AUS-IV
Detector Type Intelligent Addressable Photoelectric Smoke Detector
Communication Protocol Notifier FlashScan® SLC protocol
Addressing Rotary decimal switches
Address Range 1–159 (FlashScan systems)
Operating Voltage 15–32 VDC
Standby Current 200 µA @ 24 VDC (typical with LED enabled)
Maximum Alarm Current 4.5 mA @ 24 VDC
Operating Temperature 0°C to 50°C
Humidity Range 10% to 93% RH non-condensing
Diameter Approx. 104 mm
Height Approx. 53 mm installed on B501AUS base
Colour Ivory
Compatible Base B501AUS series and approved Notifier addressable bases
Compliance AS 7240.7